NEMA enclosures in various sizes are available with Falcon's 1kVA to 3kVA SSG and SSG-RP Series wide temperature uninterruptible power supplies (UPSs). The on-line double-conversion UPSs are UL, cUL and CE-listed to operate between -20°C to 55°C (SSG) and -30°C to 65°C (SSG-RP). All 120V UPS models are also UL 508 listed. The enclosure is high-grade and powder-coated with forced air cooling. It swings out so the user can easily control the UPS via the front panel of the UPS. Falcon’s SSG-UPS pre-configured NEMA 3R-rated UPS systems provide the ideal solution for outdoor and indoor use.
Tested and designed with robust components and materials, the SSG assures reliable operation and a long service life in stressful environments. It is a true on-line industrial UPS. The long-life batteries cut frequent battery replacements and maintenance costs. They have a 12-year life at 25°C and 4 years at 50°C. The battery banks are easily expandable to provide minutes to hours of extra battery runtime. Other options include: environmental protection, remote UPS management, environment sensors, relay cards - and much more.
The SSG UPS offers instant access to vital UPS and power information through its feature-rich, easy-to-use LCD MIMIC graphic display.
Falcon Electric is a recognized authority in industrial UPS solutions. You can count on their true on-line UPSs when you need quality and reliable backup power. For configuration options and customization, contact Westward Sales to discuss your project needs.

| Technology | |
| Category | UPS Systems |
| Battery | |
| Runtime | 6/18, 10/27, or 6/18.9 minutes (Full / Half Load time) depending on model |
| DC Bus Voltage (nominal) | 48 or 96 VDC depending on model |
| Battery Type | 12-Year Rated, Maintenance-Free, Sealed VRLA Batteries, 12 VDC, 7AH |
| Battery Pack Type | User-Replaceable, Hot-Swappable Pack Separate Enclosure from UPS Module (Internal Pack for 1.5kVA) |
| Recharge Time | 8 Hours to 90% |
| Transfer Time | < 4ms UPS to Bypass / Reverse, Auto Transfer to UPS after Overload |
| Power | |
| Rated Power | 1050 Watts | 1540 Watts | 2100 Watts |
| Nominal VA | 1500 VA | 2200 VA | 3000 VA |
| Output Voltage | User programmable: 100, 110, 115, or 120 VAC (-1 model) or 208, 220, 230, or 240 VAC (-2 model) |
| Input Voltage | Select 120 (80 to 138) VAC or 240 (160 to 276) VAC |
| Frequency | 50 / 60 Hz (auto tracking) |
| Power Factor Correction | >0.97 at full load |
| Overload | 110% for 40 seconds, 125% for 18 seconds, 150% immediate |
| Input Connection | Hardwire Terminal Block |
| Output Connection | Hardwire Terminal Block |
| Surge Protection | IEEE / ANSI C62.41 |
| Efficiency | 88% |
| Ratings | |
| Operating Temperature | -20 to 55ºC (SSG models), -30 to 65ºC (SSG-RP models). The battery service life will be reduced above 25ºC |
| Storage Temperature | -20 to 55ºC (SSG models), -30 to 65ºC (SSG-RP models) |
| Humidity | 10% to 95% non-condensing |
| Certifications | UL 1778, UL 508, cUL, FCC Class B, and CE |